Corrugated Structural Steel
| | |
The assessments are valid for A-60 fire rated constructions as follows:
• Rockwool Marine Wired Mat 105, 75 mm, 1 layer
• Rockwool Marine Wired Mat 90, 45 mm, 2 layer
• Rockwool Marine Firebatts 130, 30 mm, 2 layer
• Rockwool Marine Firebatts 100, 60 mm, 1 layer
The assessment is provided under the following restrictions:
• Products as described in test report.
• Structural core towards the fire.
• The free span of the valley below the wool may not exceed 100 mm and the thickness of the corrugated steel plating is not below 1.9 mm
• The joint between the corrugated steel sheets must be fully welded to insure “air tightness”.
• The corrugated steel structural core should not carry any vertical load.
• Pin pattern according to the description in the assessment.